Clinical Practice Guidelines (CPG) on EBMonFHIR
1.0.2 - qa-preview
This page is part of the CPG-on-EBMonFHIR Implementation Guide (1.0.2).
Active as of 2022-02-14 |
{
"resourceType" : "PlanDefinition",
"id" : "ExampleRecommendationPlan",
"meta" : {
"profile" : [
🔗 "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/recommendation-plan"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: PlanDefinition ExampleRecommendationPlan</b></p><a name=\"ExampleRecommendationPlan\"> </a><a name=\"hcExampleRecommendationPlan\"> </a><a name=\"ExampleRecommendationPlan-en-US\"> </a><p><b>knowledgeCapability</b>: computable</p><p><b>knowledgeRepresentationLevel</b>: structured</p><p><b>partOf</b>: <a href=\"PlanDefinition-ExampleRecommendation.html\">Recommendation</a></p><blockquote><p><b>Action Combination Method</b></p><ul><li>method: <span title=\"Codes:{https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method exactly}\">Exactly</span></li><li>threshold: 1</li></ul></blockquote><p><b>url</b>: <a href=\"PlanDefinition-ExampleRecommendationPlan.html\">PlanDefinition Recommendation Plan</a></p><p><b>version</b>: 1.0</p><p><b>name</b>: RecommendationPlan</p><p><b>title</b>: Recommendation Plan</p><p><b>type</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/plan-definition-type eca-rule}\">ECA Rule</span></p><p><b>status</b>: Active</p><p><b>experimental</b>: true</p><p><b>subject</b>: <a href=\"EvidenceVariable-ExampleRecommendationEligibilityCriteria5Levels.html\">PopulationExample</a></p><p><b>date</b>: 2022-02-14</p><p><b>publisher</b>: CPGonEBMonFHIR</p><p><b>description</b>: </p><div><p>Example Recommendation Plan</p>\n</div><blockquote><p><b>goal</b></p><blockquote><p><b>id</b></p>ventilator-management-goal</blockquote><p><b>category</b>: <span title=\"Codes:{http://snomed.info/sct 385857005}\">Ventilator care and adjustment (regime/therapy)</span></p><p><b>description</b>: <span title=\"Codes:\">The ventilator should be set up to provide a breath reate of at least 20 and at most per minute.</span></p><h3>Targets</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Measure</b></td><td><b>Detail[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://loinc.org 33438-3}\">Breath rate mechanical --on ventilator</span></td><td>20-24</td></tr></table></blockquote><blockquote><p><b>goal</b></p><blockquote><p><b>id</b></p>lab-ddimer-concentration-goal</blockquote><p><b>category</b>: <span title=\"Codes:{http://snomed.info/sct 410394004}\">Lab findings surveillance (regime/therapy)</span></p><p><b>description</b>: <span title=\"Codes:\">D-Dimer concentration shall be below 250 ng/mL</span></p><h3>Targets</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Measure</b></td><td><b>Detail[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://loinc.org 48066-5}\">Fibrin D-dimer DDU [Mass/volume] in Platelet poor plasma</span></td><td>?-250</td></tr></table></blockquote><blockquote><p><b>action</b></p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 432102000}\">Administration of substance (procedure)</span></p><p><b>definition</b>: <a href=\"Bundle-GuidelineRecommendationExample.html\">DrugAdministrationAction</a></p></blockquote><blockquote><p><b>action</b></p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 229824005}\">Positioning patient (procedure)</span></p><p><b>goalId</b>: ventilator-management-goal</p><p><b>definition</b>: <a href=\"ActivityDefinition-ExampleBodyPositioningAction.html\">DrugAdministrationAction</a></p></blockquote><blockquote><p><b>action</b></p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 410210009}\">Ventilator care management (procedure)</span></p><p><b>goalId</b>: ventilator-management-goal</p></blockquote><blockquote><p><b>action</b></p><blockquote><p><b>Action Combination Method</b></p><ul><li>method: <span title=\"Codes:{https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method one-or-more}\">One or More</span></li></ul></blockquote><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 89780004}\">Combined (qualifier value)</span></p><h3>Actions</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Code</b></td><td><b>GoalId</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://snomed.info/sct 410210009}\">Ventilator care management (procedure)</span></td><td>ventilator-management-goal</td></tr></table></blockquote></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeCapability",
"valueCode" : "computable"
},
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeRepresentationLevel",
"valueCode" : "structured"
},
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-partOf",
"valueCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/example/recommendation-plan/example-recommendation"
},
{
"extension" : [
{
"url" : "method",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method",
"code" : "exactly"
}
]
}
},
{
"url" : "threshold",
"valuePositiveInt" : 1
}
],
"url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ext-action-combination-method"
}
],
"url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/example/recommendation-plan/example-recommendation-plan",
"version" : "1.0",
"name" : "RecommendationPlan",
"title" : "Recommendation Plan",
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/plan-definition-type",
"code" : "eca-rule"
}
]
},
"status" : "active",
"experimental" : true,
"subjectCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/example/recommendation-eligibility-criteria",
"date" : "2022-02-14",
"publisher" : "CPGonEBMonFHIR",
"description" : "Example Recommendation Plan",
"goal" : [
{
"id" : "ventilator-management-goal",
"category" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "385857005",
"display" : "Ventilator care and adjustment (regime/therapy)"
}
]
},
"description" : {
"text" : "The ventilator should be set up to provide a breath reate of at least 20 and at most per minute."
},
"target" : [
{
"measure" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "33438-3",
"display" : "Breath rate mechanical --on ventilator"
}
]
},
"detailRange" : {
"low" : {
"value" : 20,
"system" : "http://unitsofmeasure.org",
"code" : "/min"
},
"high" : {
"value" : 24,
"system" : "http://unitsofmeasure.org",
"code" : "/min"
}
}
}
]
},
{
"id" : "lab-ddimer-concentration-goal",
"category" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "410394004",
"display" : "Lab findings surveillance (regime/therapy)"
}
]
},
"description" : {
"text" : "D-Dimer concentration shall be below 250 ng/mL"
},
"target" : [
{
"measure" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "48066-5",
"display" : "Fibrin D-dimer DDU [Mass/volume] in Platelet poor plasma"
}
]
},
"detailRange" : {
"high" : {
"value" : 250,
"system" : "http://unitsofmeasure.org",
"code" : "ng/mL"
}
}
}
]
}
],
"action" : [
{
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "432102000",
"display" : "Administration of substance (procedure)"
}
]
},
"definitionCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/example/recommendation-action/drug-administration-example"
},
{
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "229824005",
"display" : "Positioning patient (procedure)"
}
]
},
"goalId" : [
"ventilator-management-goal"
],
"definitionCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/example/recommendation-action/body-positioning-example"
},
{
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "410210009",
"display" : "Ventilator care management (procedure)"
}
]
},
"goalId" : [
"ventilator-management-goal"
]
},
{
"extension" : [
{
"extension" : [
{
"url" : "method",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method",
"code" : "one-or-more"
}
]
}
}
],
"url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ext-action-combination-method"
}
],
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "89780004",
"display" : "Combined (qualifier value)"
}
]
},
"action" : [
{
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "410210009",
"display" : "Ventilator care management (procedure)"
}
]
},
"goalId" : [
"ventilator-management-goal"
]
}
]
}
]
}