Clinical Practice Guidelines (CPG) on EBMonFHIR
1.0.2 - qa-preview

This page is part of the CPG-on-EBMonFHIR Implementation Guide (1.0.2).

: VS MII ICU Code Observation Beatmung [LOINC] - JSON Representation

Active as of 2022-01-06

Raw json | Download

{
  "resourceType" : "ValueSet",
  "id" : "vs-mii-icu-code-observation-beatmung-loinc",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet vs-mii-icu-code-observation-beatmung-loinc</b></p><a name=\"vs-mii-icu-code-observation-beatmung-loinc\"> </a><a name=\"hcvs-mii-icu-code-observation-beatmung-loinc\"> </a><a name=\"vs-mii-icu-code-observation-beatmung-loinc-en-US\"> </a><ul><li>Include these codes as defined in <a href=\"http://loinc.org\"><code>http://loinc.org</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"https://loinc.org/50984-4/\">50984-4</a></td><td>Horowitz index in Arterial blood</td></tr><tr><td><a href=\"https://loinc.org/33438-3/\">33438-3</a></td><td>Breath rate mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19839-0/\">19839-0</a></td><td>Breath rate spontaneous --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19840-8/\">19840-8</a></td><td>Breath rate spontaneous and mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76334-2/\">76334-2</a></td><td>Inspiratory time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76187-4/\">76187-4</a></td><td>Expiratory hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/75931-6/\">75931-6</a></td><td>Inspiration/Expiration time Ratio</td></tr><tr><td><a href=\"https://loinc.org/20112-9/\">20112-9</a></td><td>Tidal volume setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76222-9/\">76222-9</a></td><td>Tidal volume Ventilator --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20116-0/\">20116-0</a></td><td>Tidal volume.spontaneous --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76009-0/\">76009-0</a></td><td>Inspired minute Volume during Mechanical ventilation</td></tr><tr><td><a href=\"https://loinc.org/20118-6/\">20118-6</a></td><td>Tidal volume.spontaneous+mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76190-8/\">76190-8</a></td><td>High pressure hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76229-4/\">76229-4</a></td><td>Low pressure hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76275-7/\">76275-7</a></td><td>Inspiratory flow setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/60794-5/\">60794-5</a></td><td>Inspiratory gas flow Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/60792-9/\">60792-9</a></td><td>Expiratory gas flow Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19994-3/\">19994-3</a></td><td>Oxygen/Total gas setting [Volume Fraction] Ventilator</td></tr><tr><td><a href=\"https://loinc.org/71835-3/\">71835-3</a></td><td>Oxygen/Gas total [Pure volume fraction] Inhaled gas</td></tr><tr><td><a href=\"https://loinc.org/3147-6/\">3147-6</a></td><td>Oxygen [Partial pressure] in Exhaled gas</td></tr><tr><td><a href=\"https://loinc.org/76530-5/\">76530-5</a></td><td>Mean pressure Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76531-3/\">76531-3</a></td><td>Pressure.max Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/60827-3/\">60827-3</a></td><td>Dynamic lung compliance</td></tr><tr><td><a href=\"https://loinc.org/76248-4/\">76248-4</a></td><td>PEEP Respiratory system --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76154-4/\">76154-4</a></td><td>Airway pressure delta --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20056-8/\">20056-8</a></td><td>Airway pressure --at mean expiratory flow on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20060-0/\">20060-0</a></td><td>Airway pressure --at zero inspiratory flow on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19891-1/\">19891-1</a></td><td>Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration</td></tr><tr><td><a href=\"https://loinc.org/20079-0/\">20079-0</a></td><td>Pressure support setting Ventilator</td></tr></table></li></ul></div>"
  },
  "url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-LOINC",
  "version" : "1.0.0",
  "name" : "VS_MII_ICU_Code_Observation_Beatmung_LOINC",
  "title" : "VS MII ICU Code Observation Beatmung [LOINC]",
  "status" : "active",
  "experimental" : false,
  "date" : "2022-01-06",
  "publisher" : "https://www.medizininformatik-initiative.de",
  "description" : "Dieses ValueSet enthält Codes für die im Kontext einer Beatmung eingestellten oder gemessenen Parametern.",
  "compose" : {
    "include" : [
      {
        "system" : "http://loinc.org",
        "concept" : [
          {
            "code" : "50984-4",
            "display" : "Horowitz index in Arterial blood"
          },
          {
            "code" : "33438-3",
            "display" : "Breath rate mechanical --on ventilator"
          },
          {
            "code" : "19839-0",
            "display" : "Breath rate spontaneous --on ventilator"
          },
          {
            "code" : "19840-8",
            "display" : "Breath rate spontaneous and mechanical --on ventilator"
          },
          {
            "code" : "76334-2",
            "display" : "Inspiratory time setting Ventilator"
          },
          {
            "code" : "76187-4",
            "display" : "Expiratory hold time setting Ventilator"
          },
          {
            "code" : "75931-6",
            "display" : "Inspiration/Expiration time Ratio"
          },
          {
            "code" : "20112-9",
            "display" : "Tidal volume setting Ventilator"
          },
          {
            "code" : "76222-9",
            "display" : "Tidal volume Ventilator --on ventilator"
          },
          {
            "code" : "20116-0",
            "display" : "Tidal volume.spontaneous --on ventilator"
          },
          {
            "code" : "76009-0",
            "display" : "Inspired minute Volume during Mechanical ventilation"
          },
          {
            "code" : "20118-6",
            "display" : "Tidal volume.spontaneous+mechanical --on ventilator"
          },
          {
            "code" : "76190-8",
            "display" : "High pressure hold time setting Ventilator"
          },
          {
            "code" : "76229-4",
            "display" : "Low pressure hold time setting Ventilator"
          },
          {
            "code" : "76275-7",
            "display" : "Inspiratory flow setting Ventilator"
          },
          {
            "code" : "60794-5",
            "display" : "Inspiratory gas flow Respiratory system airway --on ventilator"
          },
          {
            "code" : "60792-9",
            "display" : "Expiratory gas flow Respiratory system airway --on ventilator"
          },
          {
            "code" : "19994-3",
            "display" : "Oxygen/Total gas setting [Volume Fraction] Ventilator"
          },
          {
            "code" : "71835-3",
            "display" : "Oxygen/Gas total [Pure volume fraction] Inhaled gas"
          },
          {
            "code" : "3147-6",
            "display" : "Oxygen [Partial pressure] in Exhaled gas"
          },
          {
            "code" : "76530-5",
            "display" : "Mean pressure Respiratory system airway --on ventilator"
          },
          {
            "code" : "76531-3",
            "display" : "Pressure.max Respiratory system airway --on ventilator"
          },
          {
            "code" : "60827-3",
            "display" : "Dynamic lung compliance"
          },
          {
            "code" : "76248-4",
            "display" : "PEEP Respiratory system --on ventilator"
          },
          {
            "code" : "76154-4",
            "display" : "Airway pressure delta --on ventilator"
          },
          {
            "code" : "20056-8",
            "display" : "Airway pressure --at mean expiratory flow on ventilator"
          },
          {
            "code" : "20060-0",
            "display" : "Airway pressure --at zero inspiratory flow on ventilator"
          },
          {
            "code" : "19891-1",
            "display" : "Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration"
          },
          {
            "code" : "20079-0",
            "display" : "Pressure support setting Ventilator"
          }
        ]
      }
    ]
  }
}